Lomita is a small, friendly city between Torrance and the Palos Verdes Peninsula. Its homes are mostly modest single-family houses and small multi-unit buildings, many with HVAC systems that are due for an upgrade.
We install heat pumps and repair heating and cooling systems throughout Lomita.
Lomita homes and climate
Most Lomita homes were built in the 1940s through the 1960s, often with furnaces in closets or garages and condensers in side yards. Some homes are larger than they look and need a 4- or 5-ton system.
Lomita sits just inland of the peninsula and gets coastal breezes, warmer summer afternoons than PV and cool winter nights. Heat pumps fit that climate well.
Because heating hours here are modest and summers are warm but not extreme, a correctly sized heat pump can replace both a gas furnace and an AC with one efficient system. Getting the size right is the key. Lomita homes vary a lot in insulation and window area, so we calculate the load instead of copying the old unit’s size.
Common Lomita HVAC work
- Replacing old furnaces and AC with heat pumps.
- Systems that are poorly matched or undersized.
- Diagnostic calls for weak cooling.
- Wall heater and furnace repairs.
- Old refrigerant systems that need replacement.
Recent jobs in Lomita
Goodman 5-ton split heat pump (July 2026)
A Lomita homeowner replaced an old system with a Goodman 5-ton split heat pump rated 14.3 SEER2, on R-32 refrigerant, with a matching multi-position air handler. We removed the old equipment, set the new system, added refrigerant for the line length and commissioned it.
Heat pump rebates for Lomita homeowners
Lomita is served by Southern California Edison, not LADWP. LADWP rebates apply only to customers in LADWP areas, such as Westchester and Playa del Rey, where the Consumer Rebate Program currently lists up to $2,500 per ton for qualifying heat pumps. TECH Clean California, the usual SCE-area heat pump incentive, has been fully reserved for single-family homes statewide since November 14, 2025.
What is open now is South Coast AQMD’s GO ZERO Phase 2 rebate, for a heat pump that replaces a gas or propane furnace, installed on or after September 4, 2026, with a finalized permit: $500 per system under 3 tons and $1,000 for 3 tons or more, doubled in designated overburdened communities. You apply for the rebate yourself, and Fuse Service provides the paperwork you need to submit a complete application, including the itemized invoice, model and serial numbers, and photos of the old and new equipment. See our rebates page.
HVAC services in Lomita
Lomita homeowners most often ask for:
- Heat pump installation: Ducted, packaged and variable-speed heat pumps, sized with a load calculation, permitted and HERS-verified.
- AC repair: Capacitors, contactors, fan motors, compressors and refrigerant leak repair.
- Furnace repair: Igniters, flame sensors, inducer motors, pressure switches, gas valves and control boards.
- AC maintenance: Coil cleaning, drain flushing and a full performance check before summer.
- Free installation quote: A written, itemized quote for a new system.
Nearby areas we serve
We also serve the communities around Lomita.
- Torrance HVAC repair
- Rancho Palos Verdes HVAC repair
- Palos Verdes Estates HVAC repair
- Gardena HVAC repair
Real Repairs From Our Technicians
You will not find a claim here that this work happened on this street, or in this city. You will find what happened on the job, and a link to the rest.
When Only One Zone Was On, the Air Got Loud
A two-zone house should not have to run both zones just to stay quiet. The house had two zones. When only one zone was on, the vents in that zone were very strong and loud. When both zones were on, the noise went away. One damper had been installed incorrectly and was closing off airflow. The air that still had somewhere to go was moving too fast, and that velocity created the noise. We will not invent a duct size or a CFM number. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
The Part That Kept Dying Was Not the Whole Problem
Overcharge and a dirty coil will raise pressures. Raised pressures will trip a system and wear its parts. The capacitor had failed every year for six years. The outdoor unit clicked and hummed and would not start, and the homeowner wanted the usual replacement. We said there was an overlooked issue causing every new capacitor to fail. The system was heavily overcharged, tripping on pressure. The coil also had a dirt layer that added to the pressure problem and needed a chemical cleaning. We will not invent a pressure or a charge weight. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
Eleven Pounds in a Seven-Pound System
The homeowners did not want a new air conditioner. They wanted the two-year-old one to do its job. Four companies had already been through the house, and so had the original installer. The two-year-old unit was running at about 24 amps on a 20-amp breaker. The charge was worse: more than eleven pounds in a system that should have held about seven. We recovered the excess, corrected the electrical side, and later saw suction saturation near 35°F with about 15°F of superheat. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
Empty of Refrigerant, and Then the Silence
Estimates without a follow-through are just expensive paper. This job had already collected some. The system was empty of refrigerant. Other companies had estimated, then stopped answering. Access was tight: a high wall, a coil between the studs, an unusual brand on the label. We confirmed a leaking evaporator, used a same-dimension coil in the 1.5-to-2-ton range, brazed under nitrogen, and had the house cooling the same day, in time for guests. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
Beyond Repair — Until It Wasn’t
A second opinion should be allowed to disagree with a death sentence. They were told the split system was beyond repair, and that the parts were banned or simply not to be had. The charge was R-410A, not the older refrigerant rumor had turned it into. The compressor was dead. The outdoor coil was packed so tightly with dirt it looked like a gray felt blanket. We replaced the compressor, flushed the lines, washed the coil, and the system performed. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
The Fins That Told on a Prior Visit
The condenser told on a prior leak search before it told us anything about our own work. The rooftop unit had already been repaired more than once. In the condenser we found four ruined patches of fins, each about six inches square, from what looked like an earlier leak search. That kind of damage cuts airflow. The customer repaired first. We had already talked about applying that repair toward a replacement if they changed course soon. A short time later, they did. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
A House Like an Oven, and a Flight Home
She called from an airport because she already knew our work. We met the return with a visit, not a replacement pitch. The heat pump died the night before a five-day trip. By the time the homeowner could call, she was already on the other side of the country, thinking about a house that would have no cooling when she got home. Our technician was waiting in the driveway when they returned. The house felt like an oven. The failure was a bottleneck at the exact point where the system is supposed to reject the heat it absorbs. Once we cleared it, cool air came back. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
Clean Coils, and the Problem That Remained
We found an approach that matched what he actually needed, rather than a cleaning sold as a cure. The coils on the old system looked bad enough that anyone could have pointed at them and called the case closed. We did not start with a cleaning. We started with the cooling complaint, and we found a compressor-side problem. We said, from the beginning, that the dirty coil was not the cause of the lack of cooling, and that cleaning it would not fix the underlying issue. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
The Estimate That Could Not Agree With the Others
You do not necessarily need a fourth expensive theory. You need someone who will test the machine. When a diagnosis changes from company to company, someone is guessing, or someone is selling, or both. This customer had already been through that. We will not pretend to quote every earlier report. What we know is that the theories did not match, the prices were high, and a two-hour visit had pointed at a zone circuit board. Boris closed the case in four minutes, at a fraction of the cost, and checked the reset and the modes before he left. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
The Break That Stopped the Cooling
The review was brief and kind. The owner reply named the failure and the result. Sometimes the failure that takes down a whole air conditioner is not a compressor and is not a tired old system. It is a line — the copper path that carries refrigerant — and if that line is torn, the system cannot do its job. The technician identified the problem quickly and repaired it. We told the customer the fact that mattered: the line was torn, we took care of it, and the cooling came back. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
A Rooftop Unit and a Crane
We named the crane in the work, because a rooftop unit does not come down by optimism. The air conditioner had broken down and needed to be replaced. That part was not in dispute. Everything after that was. Other quotes were all over the place — not only in price, but in what actually needed to be done. We were straightforward, the price was reasonable, and we finished in the timeline we had promised. The work included a rooftop outdoor unit with crane service, a new indoor ceiling coil, and insulation improvements to help prevent condensation. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
What a Normal Coil Cleaning Could Not Reach
Months later, the air conditioner was still running odor-free. The smell appeared only when the air conditioner was running. We came out more than once. We chemically cleaned the evaporator coil several times, cleaned the drain pan and the air handler, and flushed the drain line, and the odor still came back. Boris eventually found that the top of the A-shaped coil could be separated. Inside, in a spot a standard cleaning cannot reach, was old attic insulation debris trapped in the fins. He cleaned it thoroughly and flushed the system. The residual smell took time to fade. Months later, the air was still clean. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
A Three-Year-Old Furnace, Condemned Too Soon
We were glad the house had a working solution, not another winter of waiting on a replacement it did not need. Two winters is a long time to be without heat. The furnace was only three years old, and other companies had already been there with astronomical quotes, saying the furnace and the ductwork both needed to be replaced. Michael diagnosed the issue and, even without the right parts on the truck, retrofitted parts to get it fixed the same day. The price was very reasonable. We are not going to name a part the source never named. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
Slope, a Shared Line, or Both
In this condo the path out was the problem, not some dramatic refrigeration failure. Some air-conditioning failures are about a compressor. This one was about water — the quiet water a system makes when it cools a house — and whether that water had a trustworthy path out of a condo whose layout and original installation were already working against it. The issue was not straightforward. Either a missing slope could have been causing condensation carry-over, or a drain line shared with the water heater could have been the cause. We installed a pump to force the condensation down the line, and we stayed late to finish. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
A Satisfying Sentence That Was Not True
The satisfying sentence lost. The less tidy work of collecting data points won. A refrigerant leak is a satisfying sentence. It sounds precise. It explains a warm house. Sometimes it is even true. In this house, another company had already suggested a leak. We found the actual problem and fixed it. The public record does not name the failed part, and we will not invent one. The contrast the homeowner drew is the fact we will stand behind: the earlier visit pointed at a leak, and the visit that fixed the system found something else. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
Eighteen Feet Up, and a Wire Against the Housing
After the outage, the furnace would not start or stop reliably. The cause was waiting on the roof. The furnace sat on a flat roof about eighteen feet up and had been unreliable since a power outage, failing to turn on or off as it should. Another company declined the work, citing height, an un-anchored ladder, and the lack of OSHA-compliant anchors or a fixed access ladder. We climbed up. A number of things from the original installation had been done incorrectly. The igniter wire was touching the heat exchanger housing. It had melted and burned. We found it and replaced it. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
Zero Volts at the Contactor Coil
Low-voltage wiring is easy to forget when you are hanging a picture. The system does not forget. The indoor blower was running and the thermostat was calling for cooling, but the outdoor condenser was silent. Breakers were reset, the pan was dry, and the homeowner had measured essentially zero volts across the contactor coil while the system was calling. We traced the low-voltage circuit and found the break: while someone was hanging a picture, a screw had been driven through the communication and thermostat wire. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
The Dirty-Sock Smell a Coil Cleaning Missed
We will not name a cleaning method beyond this: we found the trapped hair, and we cleared it. The heat pump was less than a year old, installed the previous November, and the dirty-sock smell had been in the house since spring. The original installer had cleaned the coils twice, with little success. The second cleaning was less than a month old, and the smell was already back. We opened the factory joint where the evaporator sections connect — a joint that can be separated — and found pet hair trapped there. We cleared it. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
The Valve That Would Not Move
We treated the stuck valve as a problem to unstick, not as a part to replace on sight. The call was at a private residence inside a Beverly Hills hotel. We diagnosed a stuck reversing valve — the part on a heat pump that tells the refrigerant which way to travel. We did not start with a replacement we could not yet justify. We freed the valve using a very strong magnet. Once it was free, it could do its work again. We will not invent a gauge reading or a longer list of other repairs. The longer piece is there for anyone who wants to see the visit unfold. Read what we found
Book Now or call (213) 279-9223.
Lomita HVAC FAQs
What is R-32 refrigerant?
It’s a newer refrigerant with lower global warming potential than R-410A, now used in many new systems.
How long does a heat pump installation take?
Most single-system installations take one to two days.
Is Lomita SCE?
Yes. Lomita is served by Southern California Edison.
Book HVAC service in Lomita
Need HVAC service in Lomita? Call (213) 279-9223 or book online any time. Planning a replacement? Ask for a free installation quote.