The Damper That Made the Vents Too Loud
The house had two zones, which is supposed to be a comfort feature: you run the part of the house you are using, and you leave the rest alone. What the homeowner noticed was the opposite of comfort. When only one zone was turned on, the airflow at the vents in that zone was very strong, and it was loud. When both zones were on, the problem went away.
That pattern is already a clue. The system could move air quietly when both paths were open. When one path was closed, the remaining vents were taking more air than they were happy to take, and the speed of that air was making the noise.
What we found
One damper had been installed incorrectly. Instead of doing what a zone damper is supposed to do — open and close the right path at the right time — it was closing off airflow in a way it should not have been. With that path restricted, the air that still had somewhere to go was moving too fast. That velocity was what created the noise.
We are not going to invent a cubic-feet-per-minute reading, a duct size, or a static-pressure number we did not record. The diagnosis is enough, and it is the one we have: a damper installed incorrectly, airflow closed off, velocity too high, and noise at the vents as a result.
What this means
If a two-zone system is quiet with both zones on and loud with only one, do not assume the ducts are simply “too small” or that the system has to be converted to a single zone. Sometimes a damper is sitting wrong, and the air is being forced through whatever remains open. See our zone control system repair and air conditioning repair pages.