Why a Capacitor Failed Every Year for Six Years
The outdoor unit made a clicking noise and a hum, and it would not start. The homeowner already knew the pattern. The capacitor was out again. It had failed every year for the past six years. He wanted the capacitor replaced, as it had been replaced before.
A capacitor that dies once can be an ordinary failure. A capacitor that dies every year for six years is not ordinary. It is a symptom. Something else is punishing each new part until that part fails too. We said so at the start: there was an overlooked issue causing every new capacitor to fail.
What we found
The system was heavily overcharged. That extra refrigerant was driving the pressures up, and the system was tripping on pressure. A unit that is hammered like that will keep asking too much of its electrical parts. A capacitor living in that kind of stress will not last a year — and this one had not, not for six years running.
The coil was part of the same story. It had a layer of dirt that also added to the pressure problem, and it needed a chemical cleaning to take that layer off. Dirt on a coil makes it harder for the system to reject heat. Combined with a heavy overcharge, it is a reliable way to keep a machine in trouble.
We are not going to invent a pressure reading, a charge weight, or a superheat number we did not record. We will say what we can stand behind: the system was heavily overcharged and tripping on pressure, and the coil needed a chemical cleaning to remove a dirt layer that was making the pressure problem worse.
What this means
If you are replacing the same capacitor every season, stop treating the capacitor as the whole diagnosis. Ask what is overworking it. In this case it was a heavy overcharge, a dirty coil, and a system that was tripping on pressure. See our air conditioning repair and central air conditioning repair pages.